{"product_id":"ajax-12v-psu-for-nvr-ajax-112255","title":"Ajax 12V PSU for NVR - AJAX-112255","description":"\u003cp\u003e\u003cstrong\u003e12V PSU for NVR\u003c\/strong\u003e is a power supply unit designed to allow an Ajax NVR to operate from a low-voltage power source instead of the standard 110\/230 V~ mains supply. The module replaces the default internal power supply unit inside the NVR enclosure.\u003c\/p\u003e\n\u003cp\u003eBy powering the NVR from a low-voltage source such as a backup battery system, the device can continue operating during power outages. This ensures uninterrupted video recording and reliable surveillance, making it ideal for facilities with unstable or unavailable mains power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlternative low-voltage power supply for Ajax NVR\u003c\/li\u003e\n\u003cli\u003eSupports operation from 8–16 V⎓ power sources\u003c\/li\u003e\n\u003cli\u003eEnsures uninterrupted recording during power outages\u003c\/li\u003e\n\u003cli\u003eInstalls directly inside the NVR enclosure\u003c\/li\u003e\n\u003cli\u003eReplaces the standard 110\/230 V~ internal power supply\u003c\/li\u003e\n\u003cli\u003eSupports two operating modes depending on jumper configuration\u003c\/li\u003e\n\u003cli\u003eStandard jack plug power connection\u003c\/li\u003e\n\u003cli\u003eQuick installation using a PH1 screwdriver\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Set\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12V PSU for NVR\u003c\/li\u003e\n\u003cli\u003eTerminal adapter\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2-Years Warranty\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0273\/7297\/8236\/files\/2-Yearswarranty_480x480.png?v=1666051264\" width=\"196\" height=\"196\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAjax’s 2-year manufacturer warranty covers defects in materials or errors in the manufacturing process that may occur within 24 months from the date of sale. The warranty does not cover normal wear and tear (device body scrapes, scratches, etc.), wear of the elements caused by improper operation, and normal wear of the device components, mechanical and\/or electrical damage (including latent), exposure to direct sunlight, high humidity, and vibration or damage caused by natural disasters. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThe warranty does not cover damage to the product resulting from unauthorised repair, installation, and\/or replacement of components or programs, including the installation of updates and extensions, performed by anyone other than an authorised representative of the Limited Liability Company “Ajax Systems Manufacturing”. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eIf a device is faulty, SpyMonkey will facilitate the warranty process with the manufacturer for you. We aim to do so in a manner that is as fast and efficient as possible.\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease contact our support team at \u003ca href=\"mailto:support@SpyMonkey.com.au\"\u003esupport@SpyMonkey.com.au\u003c\/a\u003e or \u003ca href=\"tel:1300049519\"\u003e1300-049-519\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note, that we do not cover inbound shipping of the return to us however if a replacement is to be sent we will cover outbound shipping to the customer. We will need the serial number of the product and your order number. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease don’t ship us anything until you have had confirmation from our teams and they have given you an RMA number and return address.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eTech Specs\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-voltage power supply unit for Ajax NVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNVR (8-ch)\u003cbr\u003eNVR (16-ch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInstalled inside the NVR enclosure replacing the standard 110\/230 V~ PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connection Socket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 × 2.0 mm (Power jack – female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 × 2.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Cable Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 12–14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode (No Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8–16 V⎓ operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption (No Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurn-On Voltage Threshold (No Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.1 V⎓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurn-Off Voltage Threshold (No Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 V⎓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode (With Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1–16 V⎓ operating voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption (With Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurn-On Voltage Threshold (With Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1 V⎓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurn-Off Voltage Threshold (With Jumper)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.35 V⎓\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 V⎓ ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShutdown Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuiescent Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to +40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 × 123 × 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"text-align: center;\"\u003eDownload\u003c\/h3\u003e\n\u003ctable style=\"height: 54.1597px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 28.5764px;\"\u003e\n\u003ctd style=\"width: 27.654%; height: 28.5764px;\"\u003eSpecification\u003c\/td\u003e\n\u003ctd style=\"width: 72.0237%; height: 28.5764px;\"\u003e\u003ca title=\"TDS - EN - Ajax 12V PSU for NVR\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0566\/0655\/6312\/files\/TDS_-_EN_-_Ajax_12V_PSU_for_NVR.pdf?v=1747350985\" target=\"_blank\"\u003e\u003cspan class=\"download-link__name\"\u003eTDS - EN - Ajax 12V PSU for NVR\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.5833px;\"\u003e\n\u003ctd style=\"width: 27.654%; height: 25.5833px;\"\u003eUser Manual\u003c\/td\u003e\n\u003ctd style=\"width: 72.0237%; height: 25.5833px;\"\u003e\u003ca href=\"https:\/\/support.ajax.systems\/en\/manuals\/12v-psu-for-nvr\/\" title=\"Ajax 12V PSU User Manual\" rel=\"noopener\" target=\"_blank\"\u003eAjax 12V PSU User Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Ajax","offers":[{"title":"Default Title","offer_id":51348322091296,"sku":"AJAX-112255","price":69.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0273\/7297\/8236\/files\/bb693261-df7e-403f-a2c2-52008a131fa0_1024x1024_2x_2e46aaf1-9a0b-4826-806e-830da749e882.png?v=1773398588","url":"https:\/\/www.spymonkey.com.au\/products\/ajax-12v-psu-for-nvr-ajax-112255","provider":"Spy Monkey Surveillance","version":"1.0","type":"link"}